Smart Ethernet I/O ioLogik E2214 Moxa vietnam
Features and Benefits
- Front-end intelligence with patented Click&Go control logic, up to 24 rules
- Active communication with MX-AOPC UA Server
- Save time and wiring cost with peer-to-peer communication
- Supports SNMPv1/v2c/v3
- Friendly configuration via web browser
- Simplify I/O management with MXIO library for Windows or Linux platforms
- Wide operating temperature range of -40 to 75°C (-40 to 167°F)
Introduction
Moxa’s ioLogik E2200 is a new type of Ethernet micro RTU controller, which is a PC-based data acquisition and control device that uses proactive, event-based reporting to control I/O devices. Unlike traditional RTUs, which are passive and must poll for data, Moxa’s ioLogik E2200 series with Active OPC Server makes seamless connection with SCADA systems a reality. In addition, SNMP is used for communicating with an NMS (Network Management System) for IT field users. The I/O status of an Ethernet micro RTU controller can be reported and controlled automatically on-site based on user specified conditions. This report-by-exception approach, which is new to PC-based monitoring, requires far less bandwidth than traditional polling methods.
Active Alarming with Local Intelligence
The ioLogik E2200 Micro RTU supports simple and powerful Click&Go™ technology to deliver event-driven reports and allow alarm messages to be sent by email, TCP/UDP, and SMNP Trap with real-time stamps. With built-in Click&Go™ intelligence, the ioLogik E2200 micro RTU can be used for simple output control when it is triggered by input status, without the need for a PC controller. The ioLogik E2200 micro RTU reports I/O status automatically based on user-specified conditions. This report by-exception approach requires far less bandwidth than the traditional polling approach.
Towards a Smarter World with Moxa’s I/O Solutions
Smart I/O Success Stories
The innovation of Moxa’s data acquisition engineers is reflected in Moxa’s latest I/O products, which are helping companies around the world simplify the management of distributed control systems, and as a result reduce costs and create business growth. In addition, Moxa also provides innovative data acquisition software that helps businesses simplify the process of integrating I/O devices with an existing network. This smart automation software not only helps users gather data faster and more efficiently, but also helps businesses identify, assess, and monitor potential risks.
Download this 16-page Smart I/O Brochure to learn more about:
- The Smarter World Trend
- Moxa’s Innovative Designs
- Moxa’s Easy-to-Use Automation Software
- Success Stories Based on Moxa’s Smart I/O Solutions
- Moxa’s Smart IO Product Selection Guide
Related White Papers
A New Chapter in the Legacy of RS-485 Data Acquisition Devices
This white paper provides insight into the future of RS-485 data acquisition devices, and how Moxa is adding a new chapter to the legacy of RS-485 data acquisition devices.
SNMP I/O Devices Make Monitoring Environmental Conditions Easy
This paper will first explain what SNMP is, why you should use SNMP for environmental monitoring, and then discuss how an SNMP environmental monitoring device will help ease the management and implementation process.
Hardware Informations:
Dimensions (unit = mm)
Pin Assignment
I/O (left to right)
• ioLogik E2214 Specifications | |
• Inputs and Outputs | |
Digital Inputs | 6 channels |
Relay Outputs | 6 channels |
Isolation | 3k VDC or 2k Vrms |
• Digital Input | |
Sensor Type | Wet Contact (NPN or PNP) and Dry Contact |
I/O Mode | DI or Event Counter |
Dry Contact | • On: short to GND • Off: open |
Wet Contact (DI to GND) | • On: 0 to 3 VDC • Off: 10 to 30 VDC |
Common Type | 3 points per COM |
Counter Frequency | 900 Hz |
Digital Filtering Time Interval | Software Configurable |
• Relay Output | |
Type | Form A (N.O.) power relay |
Contact Current Rating | • Inductive Load: 2 A @ 30 VDC, 250 VAC, 110 VAC • Resistive Load: 5 A @ 30 VDC, 250 VAC, 110 VAC |
Minimum permitted load | 1 A @ 5 VDC |
Initial Insulation Resistance | 1000 mega-ohms (min.) @ 500 VDC |
Mechanical Endurance | 1,000,000 operations |
Electrical Endurance | 100,000 operations @ 5 A resistive load |
Contact Resistance | 100 milli-ohms (max.) |
Pulse Output | 0.3 Hz at rated load |
Note | Ambient humidity must be non-condensing and remain between 5 and 95%. The relays of the ioLogik E2214 may malfunction when operating in high condensation environments below 0° Celsius. |
• Power Requirements | |
Input Voltage | 12 to 36 VDC |
Input Current | 170 mA @ 24 VDC |
• MTBF (mean time between failures) | |
Time | 307,239 hrs |
Standard | Telcordia SR332 |
• Common Specifications | |
• LAN | |
Ethernet | 1 10/100 Mbps RJ45 port |
Protection | 1.5 kV magnetic isolation |
Protocols | Modbus/TCP (slave), TCP/IP, UDP, DHCP, BOOTP, SNMP, HTTP, CGI, SNTP, SMTP |
• Serial | |
Interface | 1 RS-485-2w terminal block port |
Parity | None |
Data Bits | 8 |
Stop Bits | 1 |
Flow Control | None |
Baudrate | 1200 to 115200 bps |
Protocols | Modbus RTU (gateway) |
• Physical Characteristics | |
Wiring | I/O cable max. 14 AWG |
Dimensions | 115 x 79 x 45.6 mm (4.53 x 3.11 x 1.80 in) |
Weight | under 250 g (0.55 lb) |
Mounting | DIN-rail or wall |
• Environmental Limits | |
Operating Temperature | Standard Models: -10 to 60°C (14 to 140°F) Wide Temp. Models: -40 to 75°C (-40 to 167°F) |
Storage Temperature | -40 to 85°C (-40 to 185°F) |
Ambient Relative Humidity | 5 to 95% (non-condensing) |
Shock | IEC 60068-2-27 |
Vibration | IEC 60068-2-6 |
Altitude | Up to 2000 m |
Note | Please contact Moxa if you require products guaranteed to function properly at higher altitudes. |
• Standards and Certifications | |
Safety | UL 508 |
EMC | EN 61000-6-2/6-4 |
EMI | CISPR 22, FCC Part 15B Class A |
EMS | IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m 1.4 GHz to 2 GHz: 3 V/m 2 GHz to 2.7 GHz: 1 V/m IEC 61000-4-4 EFT: Power: 2 kV; Signal: 1 kV IEC 61000-4-5 Surge: Power: 1 kV IEC 61000-4-6 CS: 10 V IEC 61000- |
Green Product | RoHS, CRoHS, WEEE |
Note | Please check Moxa’s website for the most up-to-date certification status. |
• Warranty | |
Warranty Period | 2 years |
Details | www.anhnghison.com |
*Because of the limited lifetime of power relays, products that use that component are covered by a 2-year warranty.