EN-50155-TN-5305-Series-Moxa-vietnam.jpg

EN 50155 TN-5305 Series Moxa vietnam


Features and Benefits 

  • 10/100BaseT(X), 4-pin M12 (D-coded), F/H duplex mode, and auto MDI/MDI-X connection
  • IP67 rated housing protection
  • Power input: 12 to 45 VDC, 18 to 30 VAC
  • Complies with all EN 50155 mandatory test items*
  • -40 to 75°C operating temperature range (T models)
    *This product is suitable for rolling stock railway applications, as defined by the EN 50155 standard. For a more detailed statement, click here: ansvietnam.com/moxa-pdf/moxa-vietnam-ansvietnam-EN_50155_Compliance.pdf

Introduction

The TN-5305 series Ethernet switches are IP67-rated for tough industrial applications. By using M12 connectors, you can rest assured that Ethernet cables will connect tightly to the switch, and will be robust enough to protect your applications from external disturbances, such as the vibration and shock encountered in the transportation industry. The space-saving TN-5305 switches can be mounted virtually anywhere, and wide operating temperature (-40 to 75°C) models are also available for use in the most extreme weather conditions. The TN-5305 Series Ethernet switches comply with a portion of EN 50155 specifications, covering operating temperature, power input voltage, surge, ESD, and vibration, making the switches suitable for a variety of industrial applications.

White Paper: Optimized Ethernet Redundancy for Inter-Consist Networks Download

Network redundancy is a critical factor in ensuring passenger safety and journey reliability in onboard railway communications for both intra-consist and inter-consist Ethernet networks. In addition, railway operators are looking for ways to more efficiently allocate resources and serve passenger demands. For example, metropolitan rail services may want to run trains with fewer consists during off-peak hours but longer trains with more consists during rush hour. Railway operators can also serve multiple markets and conserve track assets by connecting multiple consists with different destinations into one train if they will travel along the same route for at least part of the journey. 

This white paper describes how Dynamic Ring Coupling helps railway operators provide seamless onboard Ethernet redundancy with both rapid recovery times and automatic Ethernet switch configuration even when consists are rearranged mid-journey.

--------------------------------------------------------------------------------------------------------------------------------------

2015 Railway Application Guide Download

 

Moxa has provided key communications, data control, and computing infrastructure for dozens of successful major railway projects around the world. Metro, mainline, high speed rail, and conventional rolling stock applications on six continents. This brochure examines some key application scenarios and how Moxa addresses today's industrial challenges.

This brochure covers the following applications:

  • Ethernet Train Backbone
  • Onboard CCTV
  • Passenger Wi-Fi
  • Passenger Information System
  • Communication-based Train Control (CBTC)
  • Wayside Communication System
  • Condition Monitoring for Turnouts
Technology
Standards IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X)
IEEE 802.3x for Flow Control
Processing Type Store and Forward
Software Features
Processing Type Store and Forward
Interface
M12 Ports 10/100BaseT(X) auto negotiation speed, F/H duplex mode, and auto MDI/MDI-X connection
Power Requirements
Input Voltage • 24/36 VDC
• 18 to 30 VAC (47 to 63 Hz)
Note Compliant with EN 50155 on 24 VDC
Operating Voltage • 12 to 45 V
• 18 to 30 VAC (47 to 63 Hz)
Input Current • 0.28 A @ 24 VAC
• 0.10 A @ 24 VDC
• 0.08 A @ 36 VDC
Overload Current Protection Present
Connection 1 M12 socket (A-coded), single power input
Reverse Polarity Protection Present
Physical Characteristics
Housing Plastic
IP Rating IP67 protection
Dimensions 60 x 125 x 29.6 mm (2.36 x 4.92 x 1.09 in)
Weight 270 g (0.56 lb)
Installation Field-style mounting, DIN-rail mounting (with optional kit)
Environmental Limits
Operating Temperature Standard Models: -25 to 60°C (-13 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
Storage Temperature -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity 5 to 95% (non-condensing)
Standards and Certifications
Safety UL/cUL 508
EMI FCC Part 15 Subpart B Class A, EN 55032 Class A
EMS IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/m
IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV
IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV
IEC 61000-4-6 CS: 10 V
IEC 61000-4-8
Rail Traffic (for panel-mounting installations) EN 50155*, EN 50121-4
*This product is suitable for rolling stock railway applications, as defined by the EN 50155 standard. For a more detailed statement, click here ansvietnam.com/moxa-pdf/moxa-vietnam-ansvietnam-EN_50155_Compliance.pdf
Shock EN 50155, IEC 61373
Freefall IEC 60068-2-32
Vibration EN 50155, IEC 61373
Note: Please check Moxa’s website for the most up-to-date certification status.
MTBF (mean time between failures)
Time 3,451,678 hrs
Standard Telcordia SR332
Warranty
Warranty Period 5 years
Details www.anhnghison.com