Industrial Ethernet-to-Fiber Media Converters PTC-101 Series Moxa vietnam
Features and Benefits
- 10/100BaseT(X) auto-negotiation and auto-MDI/MDI-X
- Link Fault Pass-Through (LFP)
- Power failure alarm by relay output (LV model only)
- -40 to 85°C operating temperature range
- Redundant dual DC power inputs (LV model only)
- Integrated high-reliability power supply eliminates the need for external power transformer
- Compliant with EN 50121-4
- Complies with all EN 50155 mandatory test items*
*This product is suitable for rolling stock railway applications, as defined by the EN 50155 standard. For a more detailed statement, click here: ansvietnam.com/moxa-pdf/moxa-vietnam-ansvietnam-EN_50155_Compliance.pdf
Introduction
The PTC-101 Ethernet-to-fiber media converters convert from 10/100BaseT(X) to 100BaseFX. Models are available with either SC, ST, or LC connectors. The PTC-101 converters eliminate the need for additional wiring, and support IEEE 802.3 and IEEE 802.3u/x protocols with 10/100M, full/half-duplex, and MDI/MDI-X auto-sensing to provide a total solution for your industrial Ethernet networks. The PTC-101 is compliant with the mandatory sections of EN 50155, covering operating temperature, power input voltage, surge, ESD and vibration.
Dimensions
• Technology | |
Standards | IEEE 802.3 for 10BaseT IEEE 802.3u for 100BaseT(X), 100BaseFX |
• Interface | |
RJ45/M12 Ports | 10/100BaseT(X) |
Fiber Ports | 100BaseFX (SC/ST/LC connectors) |
LED Indicators | PWR1, PWR2, Fiber Link, 10/100M (TP port) |
DIP Switches | |
Alarm Contact | One relay output with current carrying capacity of 1 A @ 24 VDC (LV model only) |
• Optical Fiber | |
• Physical Characteristics | |
Housing | Metal, IP30 protection |
Dimensions | 152.15 x 123.46 x 66.65 mm (5.99 x 4.86 x 2.62 in) |
Weight | Product only: 690 g (1.52 lb) Packaged: 875 g (1.92 lb) |
• Environmental Limits | |
Operating Temperature | -40 to 85°C (-40 to 185°F) |
Storage Temperature | -40 to 85°C (-40 to 185°F) |
Ambient Relative Humidity | 5 to 95% (non-condensing) |
Conformal Coating | Available upon request |
• Power Requirements | |
Input Voltage | |
Input Current | LV-DC: 170 mA @ 20 VDC max. HV-AC: 73 mA @ 85 VDC max. HV-DC: 47 mA @ 88 VDC max. |
Connection | Removable terminal block |
Overload Current Protection | 1.6 A (protects against two signals shorted together) |
Reverse Polarity Protection | Protects against V+/V- reversal |
• Standards and Certifications | |
Safety | UL 60950-1 |
EMC | EN 55032/24 |
EMI | CISPR 32, FCC Part 15B Class A |
EMS | EN 61000-4-2 (ESD): Contact: 8 kV; Air: 15 kV EN 61000-4-3 (RS): 80 MHz to 1 GHz: 3 V/m EN 61000-4-4 (EFT): Power: 4 kV; Signal: 4 kV EN 61000-4-5 (Surge): Power: 4 kV; Signal: 4 kV EN 61000-4-6 (CS): 150 kHz to 80 MHz: 3 V/m EN 61000-4-8 (PFMF) EN 6 |
Green Product | RoHS, CRoHS, WEEE Note: Refer to the “Environmental Type Tests” table below for more detailed information. |
Freefall | IEC 60068-2-32 |
Power Automation | IEC 61850-3, IEEE 1613 |
Rail Traffic | EN 50121-4 *Please contact Moxa or a Moxa distributor for details. |
Vibration | IEC-61850-3, IEC-60870-2-2, EN 50125-3 (M12 models only) |
• MTBF (mean time between failures) | |
Time | 1,211,613 hrs |
Standard | Telcordia (Bellcore), GB |
• Warranty | |
Warranty Period | 5 years |