Serial-to-Fiber Optic Converters ICF-1150 Series Moxa vietnam
Features and Benefits
- 3-way communication: RS-232, fiber, and RS-422/485
- Rotary switch to change the pull high/low resistor value
- Extend RS-232/422/485 transmission up to:
• 40 km with single-mode
• 5 km with multi-mode - 3-way isolation protection (for “I” models only)
- -40 to 85°C wide temperature range models available
- C1D2, ATEX, and IECEx certified for harsh industrial environments
Three-Way Communication
The ICF-1150 series support 2 serial ports, with a DB9 connector for RS-232 communication and a removable terminal block for RS-422 or RS-485 communication. The 3 ports (2 serial ports and one fiber port) are completely independent. When an ICF-1150 converter receives data from any one port, it will send the data out through the other 2 ports. For example, once the ICF-1150 converter receives a command from the remote master through the fiber port, it will convert the signal and send the command through the RS-232 and RS-422/485 ports at the same time. If the user is monitoring a system running on an RS-485 network, there is no need to use an additional RS-232 to RS-485 converter to connect the laptop computer’s serial port to the RS-485 bus.
Rotary Switch for Setting the Pull High/Low Resistor
The RS-485 interface supports multi-drop or daisy-chain connections, which system engineers will use to connect serial devices such as meters, RTUs, and readers, together on the same bus. Since the number of serial devices on the same bus will cause the impedance of the data line to increase, the ICF-1150 allows users to tune the pull high/low resistor. Just rotate the switch to the appropriate value without removing the ICF-1150 from the DIN rail.
Dimensions
Pin Assignment
• Optical-Fiber Side | |
Fiber Connector | SC or ST |
Fiber Cable Requirements | |
Ring Transmission | Half-duplex |
Point-to-Point Transmission | Half-duplex or full-duplex |
• RS-232/422/485 Side | |
RS-232 Signals | TxD, RxD, GND |
RS-422 Signals | TxD+, TxD-, RxD+, RxD-, GND |
RS-485-4w Signals | TxD+, TxD-, RxD+, RxD-, GND |
RS-485-2w Signals | Data+, Data-, GND |
Baudrate | 50 bps to 921.6 kbps |
Isolation | 2 kV RMS isolation per I/O port for 1 minute |
• Physical Characteristics | |
Housing | Metal |
Dimensions | 30.3 x 70 x 115 mm (1.19 x 2.76 x 4.53 in) |
Weight | 330 g (0.73 lb) |
• Environmental Limits | |
Operating Temperature | Standard Models: 0 to 60°C (32 to 140°F) Wide Temp. Models: -40 to 85°C (-40 to 185°F) |
Storage Temperature | -40 to 85°C (-40 to 185°F) |
Ambient Relative Humidity | 5 to 95% (non-condensing) |
• Power Requirements | |
Input Voltage | 12 to 48 VDC |
Input Current | ICF-1150: 127 mA @ 12 VDC ICF-1150I: 163 mA @ 12 VDC |
Voltage Reversal Protection | Protects against V+/V- reversal |
Overcurrent Protection | 1.1 A (protects against two signals shorted together) |
• Standards and Certifications | |
Safety | UL 508 |
Hazardous Location | UL/cUL Class I Division 2 Groups A/B/C/D, ATEX Zone 2 EEx nC IIC, IECEx |
EMC | EN 55032/24 |
EMI | CISPR 32, FCC Part 15B Class B |
EMS | EN 61000-4-2 (ESD): Contact: 8 kV; Air: 15 kV EN 61000-4-3 (RS): 80 MHz to 1 GHz: 3 V/m EN 61000-4-4 (EFT): Power: 4 kV; Signal: 2 kV EN 61000-4-5 (Surge): Power: 4 kV; Signal: 0.5 kV EN 61000-4-6 (CS): 150 kHz to 80 MHz: 3 V/m EN 61000-4-8 (PFMF) |
Green Product | RoHS, CRoHS, WEEE |
Freefall | IEC 60068-2-32 |
• MTBF (mean time between failures) | |
Time | 792,085 hrs |
Standard | Telcordia (Bellcore), GB |
Water and Dust Proof | IP30 |
• Warranty | |
Warranty Period | 5 years |
Details | www.anhnghison.com |