Fiber Bypass Unit OBU-102 Series Moxa vietnam
Features and Benefits
- Supports Fast, Gigabit, and 10 Gigabit Ethernet fiber connections in SC/ST/LC connectors
- Redundant dual 12/24/48 VDC power inputs
- IP30 metal housing
- -20 to 70°C operating temperature range
- DIN-rail mounting ability
- Ultra low power consumption 0.72 W
Introduction
Moxa’s OBU-102 fiber optical bypass units add bypass relay functionality to any network node. In linear topologies, a single power outage or node failure can take out an entire chunk of the network, because communications to all the network nodes further down the line are also cut. With relay bypass, that node is instead simply bypassed in the event of a failure, and the rest of the network is unaffected.
The OBU-102 sits between a node and the network to add bypass relay functionality to any network switches that do not already support this important function. In normal operations, the OBU-102 simply acts as a gateway that forwards network traffic to and from the network switch. However, if power is lost, the OBU-102 will bypass the unpowered switch and simply pass network traffic to the next switch in the relay.
• Bypass Properties | |
Optical Switching Time | Max. 10 ms |
Insertion Loss | Max. 1.6 dB |
• Interface | |
Fiber Ports | 100M/1G/10G fiber in SC/ST/LC connector, single mode |
Rotary Switches | For configuring the boot delay interval |
• Power Requirements | |
Input Voltage | 12/24/48 VDC, redundant dual inputs |
Operating Voltage | 9.6 to 60 VDC |
Overload Current Protection | 1100 mA @ 48 VDC |
Connection | 2 removable 2-contact terminal block |
Reverse Polarity Protection | Present |
• Physical Characteristics | |
Housing | Metal |
IP Rating | IP30 protection |
Dimensions | 53.6 x 135 x 105 mm (2.11 x 5.31 x 4.13 in) |
Weight | 700 g (1.55 lb) |
Installation | DIN-rail mounting, wall mounting (with optional kit) |
• Environmental Limits | |
Operating Temperature | -20 to 70°C (-4 to 158°F) |
Storage Temperature | -40 to 85°C (-40 to 185°F) |
Ambient Relative Humidity | 5 to 95% (non-condensing) |
• Standards and Certifications | |
Safety | UL 508 |
EMC | EN 55032 Class A |
EMI | CISPR 32, FCC Part 15B Class A |
EMS | IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/m IEC 61000-4-4 EFT: Power: 1 kV; Signal: 0.5 kV IEC 61000-4-5 Surge: Power: 2 kV; Signal: 0.5 kV IEC 61000-4-6 CS: Signal: 10 V IEC 61000-4-8 |
Shock | IEC 60068-2-27 |
Freefall | IEC 60068-2-32 |
Vibration | IEC 60068-2-6 |
• Warranty | |
Warranty Period | 2 years |