Features & Benefits

  • Up to 16 IEEE 802.3at/af compliant combo PoE and Ethernet ports
  • Isolated power with wide 24 to 110 VDC power supply range
  • Complies with all EN 50155 mandatory test items*
  • -40 to 75°C operating temperature range 
  • Turbo Ring and Turbo Chain (recovery time < 20 ms @ 250 switches), and STP/RSTP/MSTP for network redundancy
  • Provides up to 30 watts per PoE port    
  • *This product is suitable for rolling stock railway applications, as defined by the EN 50155 standard. For a more detailed statement, click here:
    ansvietnam.com/moxa-pdf/moxa-vietnam-ansvietnam-EN_50155_Compliance.pdf

Introduction

The ToughNet TN-4524A-16PoE Series M12 managed Ethernet switches are designed for railway applications, including rolling stock and wayside installations. The switches use M12 and other circular connectors to ensure tight, robust connections, and guarantee reliable operation in industrial environments where vibration and shock are commonplace. The TN-4524A-16PoE Series Ethernet switches provide 24  fast Ethernet M12 ports with or without IEEE 802.3at/af compliant PoE (Power-overEthernet) function. The PoE switches are classified as power source equipment (PSE); they provide up to 30 watts of power per port, and can be used to power IEEE 802.3at/af compliant powered devices (PDs), such as IP cameras, wireless access points, and IP phones. The 24 to 110 VDC wide power input range and isolated dual power inputs not only allow you to use the same type of power source at different sites around the globe, but also increase the reliability of your communications system. Furthermore, the -40 to 75°C operating temperature and IP42-rated enclosure allow deployment in harsh environments. The TN-4524A-16PoE Series Ethernet switches are compliant with mandatory sections of EN 50155, covering operating temperature, power input voltage, surge, ESD, and vibration, as well as conformal coating and power insulation, making the switches suitable for a variety of industrial applications.

Unit: mm (in)

Technology
Standards IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X)
IEEE 802.3ab for 1000BaseT(X)
IEEE 802.3x for Flow Control
IEEE 802.1D-2004 for Spanning Tree Protocol
IEEE 802.1w for Rapid Spanning Tree Protocol
IEEE 802.1s for Multiple Spanning Tree Protocol
IEEE 802.1Q for VLAN Tagging
IEEE 802.1p for Class of Service
IEEE 802.1X for Authentication
IEEE 802.3ad for Port Trunk with LACP
Software Features
Management IPv4/IPv6, SNMP v1/v2c/v3, Telnet, LLDP, Port Mirror, Syslog, RMON, BootP, DHCP Server/Client, DHCP Option 66/67/82, TFTP, SMTP, RARP, HTTP, HTTPS, SNMP inform, Flow Control, Back pressure flow control
Filter 802.1Q VLAN, Port-Based VLAN, GVRP, IGMPv1/v2, GMRP, Static Multicast
Redundancy Protocols STP/RSTP, MSTP, Turbo Ring v1/v2, Turbo Ring v2 with DRC, Turbo Chain, Link Aggregation
Security RADIUS, TACACS+, SSL, SSH, Port Lock, Broadcast Storm Protection, Rate Limit
Time Management SNTP, NTP Server/Client, IEEE 1588v2 PTP (SW-based)
MIB MIB-II, Ethernet-like MIB, P-BRIDGE MIB, Q-BRIDGE MIB, Bridge MIB, RSTP MIB, RMON MIB Group 1, 2, 3, 9
Switch Properties
Priority Queues 4
Max. Number of VLANs 64
VLAN ID Range VID 1 to 4094
IGMP Groups 256
Interface
Fast Ethernet Front cabling, M12 D-coded 4-pin female connector, 10/100BaseT(X) auto negotiation speed, F/H duplex mode, and auto MDI/MDI-X connection
Gigabit Ethernet Front cabling, M12 X-coded 8-pin connector, 10/100/1000BaseT(X) auto negotiation speed, F/H duplex mode, auto MDI/MDI-X connection
Console Port M12 A-coding 5-pin male connector
Alarm Contact 2 relay outputs in one M12 A-coding 5-pin male connector with current carrying capacity of 1 A @ 30 VDC
Power Requirements
Input Voltage 24/36/48/72/96/110 VDC
Operating Voltage 16.8 to 137.5 VDC
Input Current Max. 6.6 A @ 24 VDC
Overload Current Protection Present
Connection M23 connector
Reverse Polarity Protection Present
Physical Characteristics
Housing Metal
IP Rating IP42 protection (optional protective caps available for unused ports)
Dimensions 347.8 x 132 x 122.3 mm (13.70 x 5.20 x 4.81 in)
Weight 3063 g (6.74 lb)
Installation Panel mounting
Environmental Limits
Operating Temperature -40 to 75°C (-40 to 167°F)
Storage Temperature -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity 5 to 95% (non-condensing)
Altitude 2000 m
Please contact Moxa if you require products guaranteed to function at higher altitudes.
Standards and Certifications
Safety UL 61010-2-201, EN 60950-1 (LVD)
EMC EN 55032, EN 55024
EMI CISPR 32, FCC Part 15B Class A
EMS IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/m
IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV
IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV
IEC 61000-4-6 CS: 10 V
IEC 61000-4-8
Rail Traffic (for panel mounting installations)
N 50155*, EN 50121-4, EN 45545-2
*This product is suitable for rolling stock railway applications, as defined by the EN 50155 standard. For a more detailed statement, click here: ansvietnam.com/moxa-pdf/moxa-vietnam-ansvietnam-EN_50155_Compliance.pdf
Shock EN 50155, IEC 61373
Freefall IEC 60068-2-31
Vibration EN 50155, IEC 61373
Note Please check Moxa’s website for the most up-to-date certification status.
MTBF (mean time between failures)
Time 429,402 hrs
Standard Telcordia SR332
Warranty
Warranty Period 5 years
Details www.anhnghison.com