Industrial Ethernet-to-Fiber Media Converters IMC-P101 Series Moxa vietnam
Features and Benefits
- 10/100BaseT(X) auto-negotiation and auto-MDI/MDI-X
- IEEE 802.3af compliant PoE PSE equipment
- Power failure alarm by relay output
- Store-and-forward mode and pass through mode
- -40 to 75°C operating temperature range (T models)
- Redundant dual DC power inputs
Introduction
IMC-P101 series Ethernet-to-fiber media converters provide Ethernet media conversion from 10/100BaseT(X) to 100BaseFX (with SC or ST connectors). These converters are classified as power source equipment (PSE), and when used in this way provide up to 15.4 watts to IEEE 802.3af compliant powered devices (PDs), eliminating the need for additional wiring. The IMC-P101 converters support IEEE 802.3/802.3u/802.3x with 10/100M, full/half-duplex, and MDI/ MDI-X auto-sensing, providing a complete solution for your industrial Ethernet network.
Patent Marking
Dimensions
• Technology | |
Standards | IEEE 802.3 for 10BaseT IEEE 802.3u for 100BaseT(X), 100BaseFX IEEE 802.3af for Power-over-Ethernet |
• Interface | |
RJ45 Ports | 10/100BaseT(X) |
Fiber Ports | 100BaseFX (SC/ST connectors) |
LED Indicators | PWR1, PWR2, Fiber Link, 10/100M (TP port), PSE Indicator |
DIP Switches | |
Alarm Contact | One relay output with current carrying capacity of 1 A @ 24 VDC |
• Optical Fiber | |
• Physical Characteristics | |
Housing | Metal |
Dimensions | 144.45 x 122.3 x 51.65 mm (5.69 x 4.81 x 2.03 in) |
Weight | Product only: 525 g (1.16 lb) Packaged: 710 g (1.56 lb) |
Installation | DIN-rail mounting, wall mounting (with optional kit) |
• Environmental Limits | |
Operating Temperature | Standard Models: 0 to 60°C (32 to 140°F) Wide Temp. Models: -40 to 75°C (-40 to 167°F) |
Storage Temperature | -40 to 85°C (-40 to 185°F) |
Ambient Relative Humidity | 5 to 95% (non-condensing) |
• Power Requirements | |
Input Voltage | 48 VDC (46 to 57 VDC), redundant inputs |
Input Current | 130 mA @ 48 VDC max. |
Connection | Removable terminal block |
Overload Current Protection | 1.6 A (protects against two signals shorted together) |
Reverse Polarity Protection | Protects against V+/V- reversal |
• Standards and Certifications | |
Safety | UL 508 |
EMC | EN 55032/24 |
EMI | CISPR 32, FCC Part 15B Class A |
EMS | EN 61000-4-2 (ESD): Contact: 8 kV; Air: 15 kV EN 61000-4-3 (RS): 80 MHz to 1 GHz: 3 V/m EN 61000-4-4 (EFT): Power: 4 kV; Signal: 4 kV EN 61000-4-5 (Surge): Power: 2 kV; Signal: 2 kV EN 61000-4-6 (CS): 150 kHz to 80 MHz: 3 V/m EN 61000-4-8 (PFMF) EN 61000-4-11 |
Green Product | RoHS, CRoHS, WEEE |
Shock | IEC 60068-2-27 |
Freefall | IEC 60068-2-32 |
Vibration | IEC 60068-2-6 |
• MTBF (mean time between failures) | |
Time | 435,210 hrs |
Standard | Telcordia (Bellcore), GB |
• Warranty | |
Warranty Period | 5 years |
Details | www.anhnghison.com |