I-O-Module-ioPAC-8500-Series-Expansion-Modules-Moxa-vietnam.jpg

I/O Module ioPAC 8500 Series Expansion Modules Moxa vietnam


Features and Benefits

  • 85M-1602-T: 16 digital inputs, 24 VDC, sink/source type
  • 85M-2600-T: 16 digital outputs, 24 VDC, sink-type
  • 85M-3800-T: 8 analog inputs, 4 to 20 mA
  • 85M-3810-T: 8 analog inputs, 0 to 10 VDC
  • 85M-3801-T: 8 analog inputs, 4 to 20 mA, 40 kHz
  • 85M-3811-T: 8 analog inputs, 0 to 10 VDC, 40 kHz
  • 85M-5401-T: 4 serial ports (RS-232/422/485)
  • 85M-6600-T: 6 RTDs

Introduction

Moxa’s 85M series modules can be installed in both ioPAC 8500 and ioPAC 8600 systems. Modules are available with DI/Os, AIs, Fast AIs, and serial interfaces, giving users a wide choice of options to choose from. Enough options are available to allow users to select the best I/O combination for their target application. All 85M modules are designed for railway industry applications, and as such are compliant with EN 50121-3-2, EN 50121-4, and EN 50155. In addition, the modules support a wide operating temperature range of -40 to 75°C.

Fast Track Integration for Wayside Condition Monitoring and Preventive Maintenace

This white paper will discuss how railway operators are adopting increasingly sophisticated condition-based maintenance regimes to control costs and improve track performance, some of the key difficulties system integrators need to overcome when deploying wayside condition monitoring systems for railway preventive maintenance, and how using a single condition monitoring platform can save time and costs for deployment and maintenance.

 

Railway Preventive Maintenance Solutions Flyer

 

See how Moxa's ioPAC 8500 RTU controllers make railway preventive maintenance easy. The RTUs provide extremely accurate data, giving engineers the information they need to identify anomalous conditions, before failures occur. The ioPAC 8500 RTUs are also designed to work reliably in harsh environments, and modules can be easily replaced to shorten system downtime.

 

85M-1602-T Specifications
Inputs and Outputs
Digital Inputs 16 channels
Isolation 3k VDC or 2k Vrms
Digital Input
Sensor Type Wet contact (NPN or PNP), dry contact
I/O Mode DI, Counter or Frequncy
Dry Contact • On: short to GND
• Off: open
Wet Contact (DI to COM) • Off: 0 to 3 VDC
• On: 10 to 30 VDC
Common Type 8 points per COM
Counter Frequency 5 kHz
Digital Filtering Time Interval Software selectable (by 0.1 ms)
Physical Characteristics
Wiring I/O cable, 16 AWG (max.)
Connector Spring-type terminal block
Environmental Limits
Operating Temperature -40 to 75°C (-40 to 176°F)
Power Requirements
Input Current 363.6 mA @ 3.3 VDC
MTBF (mean time between failures)
Time 1,132,561 hrs
Standard Telcordia SR332
 
85M-2600-T Specifications
Inputs and Outputs
Digital Outputs 16 channels
Isolation 3k VDC or 2k Vrms
Digital Output
Type Sink
I/O Mode DO or PWM
Pulse Output Frequency 5 kHz
Over-Voltage Protection 45 VDC
Over-Current Protection 2.6 A (4 channels @ 650 mA)
Over-Temperature Shutdown 175°C (typical), 150°C (min.)
Current Rating 200 mA per channel
Physical Characteristics
Wiring I/O cable, 16 AWG (max.)
Connector Spring-type terminal block
Environmental Limits
Operating Temperature -40 to 75°C (-40 to 176°F)
Power Requirements
Input Current 257.6 mA @ 3.3 VDC
MTBF (mean time between failures)
Time 792,571 hrs
Standard Telcordia SR332
 
85M-3800-T Specifications
Inputs and Outputs
Analog Inputs 8 channels
Isolation 3k VDC or 2k Vrms
Analog Input
Type Differential
Resolution 16 bits
I/O Mode 4 to 20 mA (wire off)
Accuracy ±0.1% FSR @ 25°C
±0.3% FSR @ -40 and 75°C
Sampling Rate • All channels: 100 samples/sec
• Per channel: 12.5 samples/sec
Input Impedance 125 ohms (min.)
Physical Characteristics
Wiring I/O cable, 16 AWG (max.)
Connector Spring-type terminal block
Environmental Limits
Operating Temperature -40 to 75°C (-40 to 176°F)
Power Requirements
Input Current 318.2 mA @ 3.3 VDC
MTBF (mean time between failures)
Time 1,512,906 hrs
Standard Telcordia SR332
 
85M-3810-T Specifications
Inputs and Outputs
Analog Inputs 8 channels
Isolation 3k VDC or 2k Vrms
Analog Inputs
Type Differential
Resolution 16 bits
I/O Mode 0 to 10 VDC
Accuracy ±0.1% FSR @ 25°C
±0.3% FSR @ -40 and 75°C
Sampling Rate • All channels: 100 samples/sec
• Per channel: 12.5 samples/sec
Input Impedance 200 kilo-ohms (min.)
Physical Characteristics
Wiring I/O cable, 16 AWG (max.)
Connector Spring-type terminal block
Environmental Limits
Operating Temperature -40 to 75°C (-40 to 176°F)
Power Requirements
Input Current 315.2 mA @ 3.3 VDC
MTBF (mean time between failures)
Time 1,530,690 hrs
Standard Telcordia SR332
 
85M-3801-T Specifications
Inputs and Outputs
Analog Inputs 8 channels
Isolation 3k VDC or 2k Vrms
Analog Input
Type Differential
Resolution 16 bits
I/O Mode 4 to 20 mA (wire off)
Historical Data Buffering 60 KB per channel, 6-second data buffer at 5 kHz
Accuracy ±0.1% FSR @ 25°C
±0.3% FSR @ -40 and 75°C
Sampling Rate • All channels: 40k samples/sec
• Per channel: 5k samples/sec
Input Impedance 125 ohms (min.)
Physical Characteristics
Wiring I/O cable, 16 AWG (max.)
Connector Spring-type terminal block
Environmental Limits
Operating Temperature -40 to 75°C (-40 to 176°F)
Power Requirements
Input Current 378.8 mA @ 3.3 VDC
MTBF (mean time between failures)
Time 1,426,112 hrs
Standard Telcordia SR332
 
85M-3811-T Specifications
Inputs and Outputs
Analog Inputs 8 channels
Isolation 3k VDC or 2k Vrms
Analog Inputs
Type Differential
Resolution 16 bits
I/O Mode 0 to 10 VDC
Historical Data Buffering 60 KB per channel, 6-second data buffer at 5 kHz
Accuracy ±0.1% FSR @ 25°C
±0.3% FSR @ -40 and 75°C
Sampling Rate • All channels: 40k samples/sec
• Per channel: 5k samples/sec
Input Impedance 20 mega-ohms (min.)
Physical Characteristics
Wiring I/O cable, 16 AWG (max.)
Connector Spring-type terminal block
Environmental Limits
Operating Temperature -40 to 75°C (-40 to 176°F)
Power Requirements
Input Current 378.8 mA @ 3.3 VDC
MTBF (mean time between failures)
Time 1,426,112 hrs
Standard Telcordia SR332
 
85M-6600-T Specifications
Inputs and Outputs
RTD Inputs 6 channels
Isolation 3k VDC or 2k Vrms
RTDs
Input Type • PT50, PT100, PT200, PT500 (-200 to 850°C)
• PT1000 (-200 to 350°C)
• JPT100, JPT200, JPT500 (-200 to 640°C)
• JPT1000 (-200 to 350°C)
• NI100, NI200, NI500 (-60 to 250°C)
• NI1000 (-60 to 150°C)
• NI120 (-80 to 260°C)
• Resistance of 310, 620
Sampling Rate (single channel) • All channels: 12 samples/sec
• Per channel: 2 samples/sec
Resolution 0.1°C or 0.1 ohms
Accuracy ±0.1% FSR @ 25°C
±0.3% FSR @ -40 and 75°C
Input Impedance 625 kilo-ohms (min.)
Wiring I/O cable, 16 AWG (max.)
Connector Spring-type terminal block
Environmental Limits
Operating Temperature -40 to 75°C (-40 to 176°F)
Power Requirements
Input Current 201.5 mA @ 3.3 VDC
MTBF (mean time between failures)
Time 571,446 hrs
Standard Telcordia SR332
 
85M-6810-T Specifications
Inputs and Outputs
Analog Inputs 8 channels
Isolation 3k VDC or 2k Vrms
Thermocouples
Sensor Type J (0 to 750°C), K (-200 to 1250°C), T (-200 to 350°C), E (-200 to 900°C), R (-50 to 1600°C), S (-50 to 1760°C), B (600 to 1700°C), N (-200 to 1300°C)
Millivolt Type • Mode: ±78.126 mV, ±39.062 mV, ±19.532 mV
• Fault and over-voltage protection: -35 to +35 VDC (power off); -25 to +30 VDC (power on)
Sampling Rate (single channel) • All channels: 12 samples/sec
• Per channel: 1.5 samples/sec
Resolution 16 bits
Accuracy ±0.1% FSR @ 25°C
±0.3% FSR @ -40 and 75°C
Input Impedance 1 mega-ohm (min.)
Wiring I/O cable, 16 AWG (max.)
Connector Spring-type terminal block
Environmental Limits
Operating Temperature -40 to 75°C (-40 to 176°F)
Power Requirements
Input Current 175.5 mA @ 3.3 VDC
MTBF (mean time between failures)
Time 2,324,891 hrs
Standard Telcordia SR332
 
85M-5401-T Specifications
Serial Communication
Interface 4 RS-232/422/485 ports, software selectable (DB44 female)
Isolation 3k VDC or 2k Vrms 
Note: DB44 to 4-port DB9 cable included in the package.
Serial Communication Parameters
Parity None, Even, Odd
Data Bits 7, 8
Stop Bits 1, 2
Flow Control RTS/CTS, XON/XOFF
Baudrate 300 bps to 921.6 kbps
Serial Signals
RS-232 TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS-422 Tx+, Tx-, Rx+, Rx-, GND
RS-485-4w Tx+, Tx-, Rx+, Rx-, GND
RS-485-2w Data+, Data-, GND
Physical Characteristics
Connector DB44 female
Environmental Limits
Operating Temperature -40 to 75°C (-40 to 176°F)
Power Requirements
Input Current 375.8 mA @ 3.3 VDC
MTBF (mean time between failures)
Time 596,611 hrs
Standard Telcordia SR332
 
Common Specifications
Power Requirements
Input Voltage 24 VDC (9 to 48 VDC)
Environmental Limits
Storage Temperature -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity 5 to 95% (non-condensing)
Shock IEC 60068-2-27
Vibration IEC 60068-2-6
Standards and Certifications
Safety UL 508
EMC EN 55032/24
EMI FCC Part 15 Subpart B Class A, CISPR 32
EMS IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV
IEC 61000-4-3 RS:
80 MHz to 1000 MHz: 3 V/m
1400 MHz to 2100 MHz: 3 V/m
2100 MHz to 2700 MHz: 1 V/m
IEC 61000-4-4 EFT: Power: 1 kV; Signal 0.5 kV
IEC 61000-4-5 Surge: Power: 2 kV (L-PE), 1 kV (L-L);
Rail Traffic EN 50155*, EN 50121-3-2, EN 50121-4
*Complies with a portion of EN 50155 specifications.
Warranty
Warranty Period 5 years
Details www.anhnghison.com