Features and Benefits
- Quad-band GSM/GPRS 850/900/1800/1900 MHz
- DIN-rail housing and wall-mounting housing
- 2.5 kV RMS isolation for 1 min. for all serial signals (G2151I only)
- LED indicators for GSM/GPRS and data transmission status
- Extended operating temperature from -25 to 70°C (G2111-T only)
Introduction
The OnCell G2111/G2151I series of industrial quad-band GSM/GPRS modems are designed to transmit data and short messages (SMS) over GSM/GPRS mobile networks. The modems can be used to increase the efficiency of maintenance and communication, but do not require extensive training. In addition, the modems can be mounted on a DIN rail or wall. The OnCell G212111/G2151I series modems accept a 12 to 48 VDC power input, making them suitable for use with a variety of field power sources. The serial ports feature 15 kV ESD line protection to protect the products from harmful electrical discharge, and separate RS-232 and RS-422/485 interfaces are built into the OnCell G2151I, each with 2.5 kV RMS isolation protection for one minute. The two serial interfaces on the OnCell G2151I make it ideal for attaching all kinds of devices, such as stand-alone controllers, PC COM ports, and multi-dropped electric meters. In addition, the OnCell G2111-T has an extended operating temperature (-25 to 70°C) design that makes it suitable for heavy industrial use.
White Paper:
Critical Elements of Industrial-Grade Wireless Devices
Industrial operators using commercial-grade wireless devices for mission-critical wireless applications may be getting satisfactory wireless network service, but frequent maintenance and system downtime can add up to a high total cost of ownership. In this paper, we reveal many harmful effects commonly found in industrial environments that can quickly disable a commercial-grade wireless device, and discuss the types of protection an industrial-grade wireless device should provide to ensure continuous wireless network communication...more
• Cellular Interface | |
Standards | GSM/GPRS |
Band Options | Quad-band 850/900/1800/1900 MHz |
GPRS Multi-slot Class | Class 10 |
GPRS Terminal Device Class | Class B |
GPRS Coding Schemes | CS1 to CS4 |
CSD Data Transmission Rate | Up to 14,400 bps |
Tx Power | GSM 1800/1900: 1 W EGSM 900/GSM 850: 2 W |
• Interface | |
Cellular Antenna Connectors | 1, SMA (female) |
• SIM Interface | |
Number of SIMs | 1 |
SIM Control | 3 V |
• Serial Interface | |
Number of Ports | 1 |
Serial Standards | OnCell G2111: RS-232 (DB9 female connector) OnCell G2111-T: RS-232 (DB9 female connector) OnCell G2151I: RS-232 (DB9 female connector), RS-422/485 (5-pin terminal block connector) |
ESD Protection | 15 kV (G2111 only) |
Optical Isolation | 2.5 kV (G2151I only) |
• Serial Communication Parameters | |
Data Bits | 8 |
Stop Bits | 1 |
Parity | None |
Flow Control | RTS/CTS |
Baudrate | 300 bps to 230.4 kbps |
• Serial Signals | |
RS-232 | TxD, RxD, RTS, CTS, DTR, DSR, DCD, RI, GND |
RS-422 | Tx+, Tx-, Rx+, Rx-, GND |
RS-485-4w | Tx+, Tx-, Rx+, Rx-, GND |
RS-485-2w | Data+, Data-, GND |
• Physical Characteristics | |
Housing | ABS + PC, providing IP30 protection |
Weight | 155 g (0.34 lb) |
Dimensions | 27 x 123 x 79 mm (1.06 x 4.84 x 3.11 in) |
• Environmental Limits | |
Operating Temperature | OnCell G2111/G2151I: -20 to 55°C (-4 to 131°F) OnCell G2111-T: -25 to 70°C (-22 to 158°F) |
Storage Temperature | -40 to 75°C (-40 to 167°F) |
Ambient Relative Humidity | 5 to 95% (non-condensing) |
• Power Requirements | |
Number of Power Inputs | 1 (terminal block) |
Input Voltage | 12 to 48 VDC |
Input Current | 0.625 A @ 12 VDC; 0.16 A @ 48 VDC |
• Standards and Certifications | |
Safety | UL 60950-1 |
EMC | EN 55032/24 |
EMI | CISPR 32, FCC Part 15B Class A |
EMS | IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m IEC 61000-4-4 EFT: Power: 0.5 kV IEC 61000-4-5 Surge: Power: 1 kV IEC 61000-4-6 CS: 3 V IEC 61000-4-8 |
Radio | FCC Part 22H, FCC Part 24E, EN 301 489-1, EN 301 489-7, EN 301 511 |
• MTBF (mean time between failures) | |
Time | OnCell G2111/G2111-T: 925,000 hrs OnCell G2151I: 864,000 hrs |
Standard | Telcordia SR332 |
• Warranty | |
Warranty Period | 5 years |
Details | www.anhnghison.com |