EN-50155-TN-5524-8PoE-Series-Moxa-vietnam.jpg

EN 50155 TN-5524-8PoE Series Moxa vietnam


Features and Benefits

  • IEEE 802.3af compliant PoE ports
  • Provides up to 15.4 watts at 48 VDC per PoE port
  • Isolated power inputs with universal 24 VDC power supply
  • Complies with all EN 50155 mandatory test items*
  • -40 to 75°C operating temperature range (T models)
  • Turbo Ring and Turbo Chain (recovery time < 20 ms @ 250 switches), RSTP/STP, and MSTP for network redundancy
    *This product is suitable for rolling stock railway applications, as defined by the EN 50155 standard. For a more detailed statement, click here: ansvietnam.com/moxa-pdf/moxa-vietnam-ansvietnam-EN_50155_Compliance.pdf

Introduction

The ToughNet TN-5500 series M12 PoE managed Ethernet switches are designed for railway applications, such as rolling stock, and wayside installations. The TN series switches use M12 and other circular connectors to ensure tight, robust connections, and guarantee reliable operation against environmental disturbances, such as vibration and shock. The TN-5524-8PoE series Ethernet switches provide 24 Fast Ethernet M12 ports with 8 IEEE 802.3af compliant PoE (Power-over-Ethernet) ports. The PoE switches are classified as power source equipment (PSE) and provide up to 15.4 watts of power per port, and can be used to power IEEE 802.3af compliant powered devices (PDs) (such as surveillance cameras, wireless access points, and IP phones). Models with an extended operating temperature range of -40 to 75°C are also available. The TN-5500-PoE series Ethernet switches are compliant with mandatory sections of EN 50155, covering operating temperature, power input voltage, surge, ESD, and vibration, as well as conformal coating and power insulation, making the switches suitable for a variety of industrial applications.

Patent Marking

White Paper: Optimized Ethernet Redundancy for Inter-Consist Networks Download

Network redundancy is a critical factor in ensuring passenger safety and journey reliability in onboard railway communications for both intra-consist and inter-consist Ethernet networks. In addition, railway operators are looking for ways to more efficiently allocate resources and serve passenger demands. For example, metropolitan rail services may want to run trains with fewer consists during off-peak hours but longer trains with more consists during rush hour. Railway operators can also serve multiple markets and conserve track assets by connecting multiple consists with different destinations into one train if they will travel along the same route for at least part of the journey. 

This white paper describes how Dynamic Ring Coupling helps railway operators provide seamless onboard Ethernet redundancy with both rapid recovery times and automatic Ethernet switch configuration even when consists are rearranged mid-journey.

--------------------------------------------------------------------------------------------------------------------------------------

2015 Railway Application Guide Download

 

Moxa has provided key communications, data control, and computing infrastructure for dozens of successful major railway projects around the world. Metro, mainline, high speed rail, and conventional rolling stock applications on six continents. This brochure examines some key application scenarios and how Moxa addresses today's industrial challenges.

This brochure covers the following applications:

  • Ethernet Train Backbone
  • Onboard CCTV
  • Passenger Wi-Fi
  • Passenger Information System
  • Communication-based Train Control (CBTC)
  • Wayside Communication System
  • Condition Monitoring for Turnouts
Technology
Standards IEEE 802.3af for Power-over-Ethernet
IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X)
IEEE 802.3x for Flow Control
IEEE 802.1D-2004 for Spanning Tree Protocol
IEEE 802.1w for Rapid STP
IEEE 802.1s for Multiple Spanning Tree Protocol
IEEE 802.1Q for VLAN Tagging
IEEE 802.1p for Class of Service
IEEE 802.1X for Authentication
IEEE 802.3ad for Port Trunk with LACP
Software Features
Management IPv4/IPv6, SNMP v1/v2c/v3, Telnet, LLDP, Port Mirror, Syslog, RMON, BootP, DHCP Server/Client, DHCP Option 66/67/82, TFTP, SMTP, RARP, HTTP, HTTPS, SNMP inform, Flow Control, Back pressure flow control
Filter 802.1Q VLAN, Port-Based VLAN, GVRP, IGMPv1/v2, GMRP, Static Multicast
Redundancy Protocols STP/RSTP, MSTP, Turbo Ring v1/v2, Turbo Chain, Link Aggregation
Security RADIUS, TACACS+, SSL, SSH, Port Lock, Broadcast Storm Protection, Rate Limit
Time Management SNTP, NTP Server/Client, IEEE 1588v2 PTP (software-based)
Industrial Protocols EtherNet/IP, Modbus/TCP
MIB MIB-II, Ethernet-like MIB, P-BRIDGE MIB, Q-BRIDGE MIB, Bridge MIB, RSTP MIB, RMON MIB Group 1, 2, 3, 9
Switch Properties
Priority Queues 4
Max. Number of VLANs 64
VLAN ID Range VID 1 to 4094
IGMP Groups 256
Interface
Fast Ethernet Front cabling, M12 D-coded 4-pin female connector, 10/100BaseT(X) auto negotiation speed, F/H duplex mode, and auto MDI/MDI-X connection
Console Port M12 A-coded 5-pin male connector
Alarm Contact 2 relay outputs in one M12 A-coded 5-pin male connector with current carrying capacity of 3 A @ 30 VDC
Power Requirements
Input Voltage 24 VDC
Operating Voltage 16.8 to 30 VDC
Input Current 8.4 (max.) @ 24 VDC
Overload Current Protection Present
Connection M23 connector
Reverse Polarity Protection Present
Physical Characteristics
Housing Metal
IP Rating IP40 protection (optional protective caps available for unused ports)
Dimensions 390 x 132 x 122.3 mm (15.35 x 5.20 x 4.81 in)
Weight 3,506 g (7.73 lb)
Installation Panel-mounting kit
Environmental Limits
Operating Temperature -40 to 75°C (-40 to 167°F)
Storage Temperature -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity 5 to 95% (non-condensing)
Altitude 2000 m 
Please contact Moxa if you require products guaranteed to function at higher altitudes
Standards and Certifications
Safety UL/cUL 508
EMI FCC Part 15 Subpart B Class A, EN 55032 Class A
EMS IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/m
IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV
IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV
IEC 61000-4-6 CS: 10 V
IEC 61000-4-8
Rail Traffic (for panel-mounting installations) EN 50155*, EN 50121-4, EN 45545-2 
*This product is suitable for rolling stock railway applications, as defined by the EN 50155 standard. For a more detailed statement, click here: ansvietnam.com/moxa-pdf/moxa-vietnam-ansvietnam-EN_50155_Compliance.pdf
Shock EN 50155, IEC 61373
Freefall IEC 60068-2-32
Vibration EN 50155, IEC 61373 
Note: Please check Moxa’s website for the most up-to-date certification status.
MTBF (mean time between failures)
Time 663,533 hrs
Standard Telcordia SR332
Warranty
Warranty Period 5 years
Details www.anhnghison.com