IEC-61850-3-PT-7828-Series-Moxa-vietnam.jpg

IEC 61850-3 PT-7828 Series Moxa vietnam


Features and Benefits  Substation Reference Book

  • IEC 61850-3, IEEE 1613 (power substations) and EN 50121-4 (railway applications) compliant
  • Complies with a portion of EN 50155 specifications
  • Turbo Ring and Turbo Chain (recovery time < 20 ms @ 250 switches), RSTP/STP, and MSTP for network redundancy
  • Up to 12 ports with M12 connectors
  • Isolated redundant power supplies with universal 24 VDC, 48 VDC, or 110/220 VDC/VAC power supply range
  • Supports multicast routing protocols PIM-DM/DVMRP
  • -40 to 85°C operating temperature range

Introduction

The PowerTrans PT-7828 switches are high performance Layer 3 Ethernet switches that support Layer 3 routing functionality to facilitate the deployment of applications across networks. The PT-7828 switches are also designed to meet the strict demands of power substation automation systems (IEC 61850-3, IEEE 1613), and railway applications (EN 50121-4).
The PT-7828’s Gigabit and Fast Ethernet backbone, redundant ring, and 24 VDC, 48 VDC, or 110/220 VDC/VAC dual isolated redundant power supplies increase the reliability of your communications and save on cabling and wiring costs. The modular design of the PT-7828 makes network planning easy, and allows greater flexibility by letting you install up to 4 Gigabit ports and 24 Fast Ethernet ports. Optional front or rear wiring makes the PT-7828 switches suitable for a variety of applications.

This product supports expansion modules. Click here for info on available modules. 

Brochure

IEC 61850 Substation Solutions

IEC 61850 Substation Solutions BrochureMaximizing a power substation’s availability and safety is the ultimate goal for both transmission grid operators and SAS (Substation Automation System) integrators. A properly optimized SAS ensures safe and continuous operation of substations. This brochure examines some key application scenarios that involve availability and safety, and considers the practical concerns electricity suppliers must account for when planning substation upgrades. In each case the focus is on how Moxa’s communication and computing solutions best minimize error probability, detect errors faster, and speed up fault corrections within the context of IEC 61850.......more

Technology
Standards IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X) and 100BaseFX
IEEE 802.3ab for 1000BaseT(X)
IEEE 802.3z for 1000BaseX
IEEE 802.3x for Flow Control
IEEE 802.1D-2004 for Spanning Tree Protocol
IEEE 802.1s for Multiple Spanning Tree Protocol
IEEE 802.1w for Rapid STP
IEEE 802.1Q for VLAN Tagging
IEEE 802.1p for Class of Service
IEEE 802.1X for Authentication
IEEE 802.3ad for Port Trunk with LACP
Software Features
Management IPv4/IPv6, SNMPv1/v2c/v3, DHCP Server/Client, BootP, TFTP, SMTP, RARP, RMON, HTTP, HTTPS, Telnet, DHCP Option 66/67/82, LLDP, Flow Control, Back Pressure Flow Control, SNMP Inform, Port Mirror, Syslog
Filter IGMPv1/v2/v3, GMRP, GVRP, 802.1Q, Q-in-Q VLAN
Redundancy Protocols STP/RSTP, MSTP, Turbo Ring v1/v2, Turbo Chain, Link Aggregation, VRRP
Security RADIUS, TACACS+, SSL, SSH, Port Lock, Broadcast Storm Protection
Unicast Routing Static routing, RIP V1/V2, OSPF
Multicast Routing DVMRP and PIM-DM
Time Management SNTP, NTP Server/Client, IEEE 1588v2 PTP
Industrial Protocols EtherNet/IP, Modbus/TCP
MIB MIB-II, Ethernet-like MIB, P-BRIDGE MIB, Q-BRIDGE MIB, Bridge MIB, RSTP MIB, RMON MIB Groups 1, 2, 3, 9
Power Substation IEC 61850 QoS
Switch Properties
Priority Queues 4
Max. Number of VLANs 64
VLAN ID Range VID 1 to 4094
IGMP Groups 256
Interface
Fast Ethernet Slots 1, 2, and 3 for combinations of 2, 4, 6, or 8-port PM-7200 Fast Ethernet modules with 10/100BaseT(X) (TP/M12 interface), 100BaseFX (SC/ST/MTRJ connector), or 100BaseSFP
Gigabit Ethernet Slot 4 for 2 or 4-port PM-7200 Gigabit Ethernet combo module, 10/100/1000BaseT(X) or 1000BaseSFP
Console Port RS-232 (RJ45)
Alarm Contact 1 relay output with current carrying capacity of 3 A @ 30 VDC or 3 A @ 240 VAC
Power Requirements
Input Voltage • 24 VDC
• 48 VDC
• 110/220 VDC/VAC
Operating Voltage • 18 to 36 V (24 VDC)
• 36 to 72 V (48 VDC)
• 88 to 300 VDC, 85 to 264 VAC (110/220 VDC/VAC)
Input Current (all ports are equipped with fiber)• Max. 2.38 A @ 24 VDC
• Max. 1.12 A @ 48 VDC
• Max. 0.59/0.30 A @ 110/220 VDC
• Max. 0.49/0.26 A @ 110/220 VAC
Overload Current Protection Present
Connection 10-pin terminal block
Reverse Polarity Protection Present
Physical Characteristics
Housing Aluminum alloy
IP Rating IP30 protection
Dimensions 440 x 44 x 325 mm (17.32 x 1.73 x 12.80 in)
Weight 5900 g (13.11 lb)
Installation 19-inch rack mounting
Environmental Limits
Operating Temperature -40 to 85°C (-40 to 185°F), cold start requires min. of 100 VAC at -40°C
Storage Temperature -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity 5 to 95% (non-condensing)
Standards and Certifications
Safety UL 60950-1
EMI FCC Part 15 Subpart B Class A, EN 55032 Class A
EMS IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 35 V/m
IEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kV
IEC 61000-4-5 Surge: Power: 4 kV; Signal: 4 kV
IEC 61000-4-6 CS: 10 V
IEC 61000-4-8
IEC 61000-4-11
Electrical Substation IEC 61850-3, IEEE 1613
Rail Traffic EN 50155*, EN 50121-4
*Complies with a portion of EN 50155 specifications. Please contact Moxa or a Moxa distributor for details.
Transportation NEMA TS2
MTBF (mean time between failures)
Time 393,828 hrs
Standard Telcordia SR332
Warranty
Warranty Period 5 years
Details www.anhnghison.com